Electrical Modules

Wholesaler of a wide range of products which include delta cliq ii redundancy modules series drr-20a and yf2a14-020vb3xleax.

Delta CliQ II Redundancy Modules Series DRR-20A

Request Callback

₹ 1000 / Piece Get Latest Price

Product Brochure
Input Voltage24V
Country of OriginMade in India
Output Current20A
Voltage Drop Between Input and OutputTypical 0.65V
Unit Weight0.38 kg (0.84 lb)
Nominal Input Voltage24-48Vdc
Model Name / NumberDRR-20A
BrandDelta
Input Voltage Range22-60Vdc
Input Current(1+1 Redundancy) = Nom. 2 x 12.5Amps (N+1 Redundancy) = Nom. 2 x 10 Amps (Single use)= Nom. 20 Amps
Efficiency at 100% load> 97% typ.
Power DissipationStandby Mode: < 1W Operating Mode: < 15W
Case Chassis / CoverAluminium
IndicatorGreen LED (DC OK): Vin1 and Vin2
Cooling SystemConvection
Input Terminal3 Pins (Rated 300V/30A)
Output Terminal4 Pins (Rated 300V/30A)
Noise Sound Pressure Level (SPL)< 40dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput / Output: AWG 12-10
Dimensions121 x 50 x 122.1 mm 4.76" x 1.97" x 4.81"
Overload / Overcurrent< 25A, No Damage
Short Circuit< 25A, No Damage
Degree of ProtectionIP20
Protection Against ShockClass III with Primary Earth connection
MTBF> 800,000 hrs. as per Telcordia SR-332 (I/P: 24Vdc and 48Vdc, O/P: 100% load, Ta: 25 DegreeC)
Electrical SafetySIQ Bauart: EN 62368-1 UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), U
Galvanic IsolationInput & Output / PE: 1.5 KVac
Industrial Control EquipmentUL/cUL recognized: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
Hazardous Location / ATEX(For DRR-20A) cCSAus: CSA C22.2 No. 213-M1987 and ANSI / ISA 12.12.01:2007 [Class I, Division 2, Gro
Electrical Equipments of MachinesEN/BS EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power InstallationsIEC/EN/BS EN 62477-1 / IEC 62103
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic
Emission(CE & RE) Generic Standards: CISPR 32, EN/BS EN 55032, KN 32 (DRR-20N and DRR-40N only), EN/BS EN 55
ImmunityGeneric Standards: EN/BS EN 55024, EN/BS EN 61000-6-2, KN 35 (DRR-20N and DRR-40N only)

Minimum order quantity: 1 Piece

Analog Corporation Offer Delta’s CliQ II redundancy modules offer a variable input and output voltage from 22 Vdc to 60 Vdc. The DRR-20☐ and DRR-40☐ can operate over a wide temperature range of -40°C to -80°C. The state-of-the-art design is made to withstand harsh industrial environments. The rugged, compact aluminium case is shock and vibration resistant according to IEC 60068-2 standard. Due to the wide input and output voltage range from 22 Vdc to 60 Vdc, the redundancy modules are able to support power supply in parallel operation. These modules also have an alarm relay contact as an indicator. 

Highlights & Features
  • Wide input and output range of 22-60Vdc
  • Very wide operating temperature from -40°C to +80°C
  • Built-in 2 channel DC OK signal and alarm relay contact
  • Support N+1 Redundancy connection
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
  • Hazardous Locations approval to ATEX and Class I, Div 2 (DRR-20A)
  • IP20 Certified
  • Certified according to IEC/EN/UL 62368-1

YF2A14-020VB3XLEAX

Request Callback

₹ 600 / Piece Get Latest Price

Product Brochure
Connection type head A Female connector, M12, 4-pin, straight, A-coded
Connection type head B Flying leads
Locking plug connector Screw connection
Connector material TPU
Connector color Black
Locking nut material Zinc die-cast, nickel-plated
Seal material FKM
Tightening torque 0.6 Nm
Width across flats 13
Cable 2 m, 4-wire, PVC
Jacket material PVC
Jacket color Gray
Cable diameter 5 mm
Conductor cross section 0.34 mm²
Shielding Unshielded
Bending radius
Flexible use > 10 x cable diameter
Stationary position > 5 x cable diameter
Nominal voltage, cable 300 V AC
Test voltage, cable 2,000 V AC
Reference voltage
250 V AC
250 V DC
Rated impulse voltage 2.5 kV
Current loading 4 A
Signal type Sensor/actuator cable
Application

Zones with chemicals

Uncontaminated zones

Authorizations

CE

UL

UL File No. E335179
Enclosure rating IP65 / IP66K / IP67
Operating temperature
Flexible use –5 °C ... +80 °C
Stationary position –30 °C ... +80 °C
Head –25 °C ... +85 °C
Contamination rating 3
Insulation resistance 100 MΩ
Overvoltage category III
Specific insulation resistance 30 mΩ
Thermal resistance, piping Flame retardant according to UL 1581 VW1 / CSA FT1
X

Contact Us

Amit Bheda (Director)
Analog Corporation
R.S.No. 171, Plot No 27 - 32, Classic Industrial Area, Dhebar Road - South, Rajkot - 360001, Gujarat, India

Get Directions
Send Email
Share: