We offer a range of panel mount power supplies for different needs. The latest PMT2 series has a slim form factor and is competitively priced for general industrial applications.
₹ 1000 / Piece Get Latest Price
| Output Voltage | 15V DC |
| Dimensions (L x W x H) | 99 x 82 x 29 mm 3.90" x 3.23" x 1.14" |
| Output Current | 3.4A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-15V50W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 13.5-16.5Vdc |
| Output Power | 51W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Wire | AWG 18-12 Current rating can refer to page6 "Wire AWG Table" |
| Unit Weight | 0.176 kg (0.39 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 16.5V-21.0V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16 cULus: UL 62368-1, and CAN/CSA C22.2 No. 62368- |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title |
| Immunity | EN/BS EN 55035, KN 35 Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1 |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 24V DC |
| Dimensions (L x W x H) | 99 x 82 x 29 mm 3.90" x 3.23" x 1.14" |
| Output Current | 2.2A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-24V50W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 21.6-26.4Vdc |
| Output Power | 53W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | SGCC / Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | M3.5 x 5 Pins (Rated 300V/20A) |
| Noise Sound Pressure Level (SPL) | AWG 18-12 Current rating can refer to page6 "Wire AWG Table" |
| Unit Weight | 0.176 kg (0.39 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 26.4V-33.6V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with Primary Earth connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16 cULus: UL 62368-1, and CAN/CSA C22.2 No. 62368- |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 35V |
| Dimensions (L x W x H) | 99 x 82 x 29 mm 3.90" x 3.23" x 1.14" |
| Output Current | 1.45A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-36V50W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 32.4-39.6Vdc |
| Output Power | 52.2W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | SGCC / Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.176 kg (0.39 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 39.6V-48.6V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16 cULus: UL 62368-1, and CAN/CSA C22.2 No. 62368- |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title |
| Immunity | EN/BS EN 55035, KN 35 Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 48V DC |
| Dimensions (L x W x H) | 99 x 82 x 29 mm 3.90" x 3.23" x 1.14" |
| Output Current | 1.1A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-48V50W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 43.2-52.8Vdc |
| Output Power | 52.8W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.176 kg (0.39 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 52.8V-64.8V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16 cULus: UL 62368-1, and CAN/CSA C22.2 No. 62368- |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title |
| Immunity | EN/BS EN 55035, KN 35 Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 12V DC |
| Dimensions (L x W x H) | 99 x 82 x 29 mm 3.90" x 3.23" x 1.14" |
| Output Current | 4.2A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-12V50W2BA |
| Mounting Type | Panel Mount |
| Output Voltage Adjustment Range | 10.8-13.2Vdc |
| Output Power | 50.4W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.176 kg (0.39 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 13.2V-17.4V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16 cULus: UL 62368-1, and CAN/CSA C22.2 No. 62368- |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title |
| Immunity | EN/BS EN 55035, KN 35 Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
| Voltage Fluctuation and Flicker | IEC 61000-4-11 |
Minimum order quantity: 1 Piece
Amit Bheda (Director)
Analog Corporation
R.S.No. 171, Plot No 27 - 32, Classic Industrial Area, Dhebar Road - South, Rajkot - 360001, Gujarat, India