We offer a range of panel mount power supplies for different needs. The latest PMT2 series has a slim form factor and is competitively priced for general industrial applications.
₹ 1000 / Piece Get Latest Price
| Output Voltage | 12V DC |
| Dimensions (L x W x H) | 215 x 115 x 30 mm 8.46" x 4.53" x 1.18" |
| Output Current | 29A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-12V350W2BR |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 10.8-13.2Vdc |
| Output Power | 348W |
| Nominal Input Voltage | 100-120Vac, 200-240Vac (Selectable by Switch) |
| Input Voltage Range | 90-132Vac, 180-264Vac (Selectable by Switch) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Force Cooling |
| Wire | AWG 18-12 Current rating can refer to page 6 "Wire AWG Table" |
| Unit Weight | 0.833 kg (1.84 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -40 DegreeC to +70 DegreeC |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Overvoltage | 13.2V-17.4V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*6connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | PMT-12V350W2BR: TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 CB scheme: |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to FCC Title |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 61000-6-1 |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 24V DC |
| Dimensions (L x W x H) | 215 x 115 x 30 mm 8.46" x 4.53" x 1.18" |
| Output Current | 14.6A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-24V350W2BR |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 21.6-26.4Vdc |
| Output Power | 350.4W |
| Nominal Input Voltage | 100-120Vac, 200-240Vac (Selectable by Switch) |
| Input Voltage Range | 90-132Vac, 180-264Vac (Selectable by Switch) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Force Cooling |
| Unit Weight | 0.833 kg (1.84 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -40 DegreeC to +70 DegreeC |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Overvoltage | 26.4-33.6V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*6connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | PMT-24V350W2BR: TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 CB scheme: |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to FCC Title |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 61000-6-1 |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 36V |
| Dimensions (L x W x H) | 215 x 115 x 30 mm 8.46" x 4.53" x 1.18" |
| Output Current | 9.7A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-36V350W2BR |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 32.4-39.6Vdc |
| Output Power | 349.2W |
| Nominal Input Voltage | 100-120Vac, 200-240Vac (Selectable by Switch) |
| Input Voltage Range | 90-132Vac, 180-264Vac (Selectable by Switch) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Force Cooling |
| Unit Weight | 0.833 kg (1.84 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -40 DegreeC to +70 DegreeC |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Overvoltage | 39.6V-48.6V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*6connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | PMT-36V350W2BR: TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 CB scheme: |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to FCC Title |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 61000-6-1 |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 48V DC |
| Dimensions (L x W x H) | 215 x 115 x 30 mm 8.46" x 4.53" x 1.18" |
| Output Current | 7.3A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name / Number | PMT-48V350W2BR |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 43.2-52.8Vdc |
| Output Power | 350.4W |
| Nominal Input Voltage | 100-120Vac, 200-240Vac (Selectable by Switch) |
| Input Voltage Range | 90-132Vac, 180-264Vac (Selectable by Switch) |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Force Cooling |
| Unit Weight | 0.833 kg (1.84 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -40 DegreeC to +70 DegreeC |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% (Non-Condensing) |
| Overvoltage | 52.8V-64.8V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*6connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | PMT-48V350W2BR: TUV Bauart: EN 62368-1 UL/cUL: UL 62368-1, and CAN/CSA C22.2 No. 62368-1 CB scheme: |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to FCC Title |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 61000-6-1 |
Minimum order quantity: 1 Piece
Amit Bheda (Director)
Analog Corporation
R.S.No. 171, Plot No 27 - 32, Classic Industrial Area, Dhebar Road - South, Rajkot - 360001, Gujarat, India