We offer a range of panel mount power supplies for different needs. The latest PMT2 series has a slim form factor and is competitively priced for general industrial applications.
₹ 1000 / Piece Get Latest Price
| Output Voltage | 15V DC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm 5.08" x 3.82" x 1.18" |
| Output Current | 7A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-15V100W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 13.5-16.5Vdc |
| Output Power | 105W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.285 kg (0.63 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 16.5V-21.0V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN |
| Immunity | EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 12V DC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm 5.08" x 3.82" x 1.18" |
| Output Current | 8.5A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-12V100W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 10.8-13.2Vdc |
| Output Power | 102W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.285 kg (0.63 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Power De-rating | > 50 DegreeC de-rate power by 2% / DegreeC < 115Vac de-rate power by 0.6% / V (85% load @ 90Vac) |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 13.2V-17.4V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN |
| Immunity | EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 24V DC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm 5.08" x 3.82" x 1.18" |
| Output Current | 4.5A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-24V100W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 21.6-26.4Vdc |
| Output Power | 108W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Input Frequency Range | 47-63Hz |
| Input Current | 1.9A typ. @ 115Vac, 1.2A typ. @ 230Vac |
| Efficiency at 100% load | 90.0% typ. @ 230Vac |
| Inrush Current | 55A typ. @ 230Vac (Cold Start) |
| Leakage Current | < 0.5mA @ 240Vac |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.285 kg (0.63 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 26.4-33.6V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 36V |
| Dimensions (L x W x H) | 129 x 97 x 30 mm 5.08" x 3.82" x 1.18" |
| Output Current | 3A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-36V100W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 32.4-39.6Vdc |
| Output Power | 108W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.285 kg (0.63 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 39.6V-48.6V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
Minimum order quantity: 1 Piece
₹ 1000 / Piece Get Latest Price
| Output Voltage | 48V DC |
| Dimensions (L x W x H) | 129 x 97 x 30 mm 5.08" x 3.82" x 1.18" |
| Output Current | 2.3A |
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
| Country of Origin | Made in India |
| Model Name/ Number | PMT-48V100W2BA |
| Mounting Type | Panel Mount |
| Brand | Delta |
| Output Voltage Adjustment Range | 43.2-52.8Vdc |
| Output Power | 110W |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Case Chassis / Cover | Aluminium / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.285 kg (0.63 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
| Operating Temperature | -30 DegreeC to +70 DegreeC (-40 DegreeC Cold Start) |
| Storage Temperature | -40 DegreeC to +85 DegreeC |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Overvoltage | 52.8V-64.8V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
| Over Temperature | Latch Mode |
| Protection Against Shock | Class I with PE*4 connection |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25 DegreeC) |
| Expected Cap Life Time | 10 years (230Vac, 50% load @ 40 DegreeC) |
| Electrical Safety | TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
| Safety Entry Low Voltage | SELV |
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) |
| Emission | (CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN |
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
| Harmonic Current Emissions | IEC/EN/BS EN 61000-3-2, Class A |
Minimum order quantity: 1 Piece
Amit Bheda (Director)
Analog Corporation
R.S.No. 171, Plot No 27 - 32, Classic Industrial Area, Dhebar Road - South, Rajkot - 360001, Gujarat, India