Delta DRC 030Watt SMPS Power Supply

Delta’s feature-rich DIN rail power supplies offers start-up at -40°C, Advanced Power Boost and smart monitoring functions on selected CliQ models. To fulfill the demands in maritime applications, CliQ M series complies with ABS and DNV-GL safety standards. Several CliQ models are also certified to ATEX and Class I, Div 2 for use in hazardous locations.

Delta CHROME II Series DRC-12V030W1RZ

Request Callback

₹ 1000 / Piece Get Latest Price

Product Brochure
Output Voltage12V DC
Dimensions (L x W x H)87.5 x 35.0 x 55.0 mm 3.44" x 1.38" x 2.17"
Output Current2A
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Country of OriginMade in India
Output Voltage Adjustment Range10.8-13.2 Vdc
Output Power24W
Nominal Input Voltage100-240 Vac
Input Voltage Range85-264 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
Input Current< 0.7 A @ 115 Vac < 0.5 A @ 230 Vac
Case Chassis / CoverPlastic
IndicatorGreen LED DC OK
Cooling SystemConvection
Input TerminalM2.5 x 2 Pins (Rated 300 V / 16 A)
Output TerminalM2.5 x 2 Pins (Rated 300 V / 16 A)
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
Overvoltage< 18 V, SELV Output, Latch Mode
Overload / Overcurrent101 - 150% of rated load current, Auto-recovery Continuous current limit Mode (Vo > 80%)
Over TemperatureLatch Mode
Degree of ProtectionIP20
Internal FuseT3.15 A / 250 V
MTBFTelcordia SR-332: > 700,000 hrs I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25 DegreeC
Expected Cap Life Time10 years (115 Vac & 230 Vac, 50% load @ 40 DegreeC)
Electrical SafetyCB scheme: IEC 62368-1, IEC/EN/BS EN 61010-1/-2-201, IEC 60335-1, IEC/EN/BS EN 61558-1/-2-16 TUV Bau
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility
Galvanic IsolationInput to Output 4.0 kVac
EmissionCISPR 32, EN/BS 55032, AS/NZS CISPR32, EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN/BS 61000
ImmunityEN/BS 55035, KS C 9835, EN/BS 61000-6-2 Compliance to EN 61000-6-1
Harmonic Current EmissionsIEC/EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN 61000-3-3
Component Power Supply for General UseEN 61204-3

Minimum order quantity: 1 Piece

Analog Corporation Offer The Chrome II Series is Delta’s latest DIN rail power supply. It features 15 W / 30 W / 60 W / 100 W models with up to 92.16 W maximum output. It has 12 V, 24 V, and 48 V nominal voltage outputs and accepts 85-264 Vac universal voltage input. It boasts a compact design to be aligned with DIN 43880, a standard that defines dimensions for distribution boards of building control and home automation systems. The Series is also certified to IEC/EN 60335-1, IEC 61558-1, and IEC 61558-2-16 to ensure electrical safety for distribution boards. All the above features make the Series suitable for building automation and household appliances. The double-isolated input eliminates the need of an earth connection for a low leakage current. It complies to DOE VI energy efficiency standard with its lower no-load power consumption. 

Highlights & Features
  • Class II, Double Isolation (No Earth connection is required)
  • Mechanical dimensions are designed to meet DIN 43880 for building automation
  • Low no load power consumption and compliance with DOE VI efficiency standard
  • NEC Class 2 / Limited Power Source (LPS) certified
  • Over Voltage Category III

Delta CHROME II Series DRC-24V030W1RZ

Request Callback

₹ 1000 / Piece Get Latest Price

Product Brochure
Output Voltage24V DC
Dimensions (L x W x H)87.5 x 35.0 x 55.0 mm 3.44" x 1.38" x 2.17"
Output Current1.5A
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Country of OriginMade in India
Output Voltage Adjustment Range21.6-26.4 Vdc
Output Power36W
Nominal Input Voltage100-240 Vac
Input Voltage Range85-264 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
Case Chassis / CoverPlastic
IndicatorGreen LED DC OK
Cooling SystemConvection
Input TerminalM2.5 x 2 Pins (Rated 300 V / 16 A)
Output TerminalM2.5 x 2 Pins (Rated 300 V / 16 A)
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
Unit Weight0.13 kg (0.29 lb)
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz @ 2 G; 10 min per cycle, 60 min for X, Y, Z direction
Operating Temperature-0 DegreeC to +70 DegreeC
Storage Temperature-40 DegreeC to +85 DegreeC
Power De-ratingTemperature: > 50 DegreeC de-rate power by 2% / DegreeC Input Voltage: < 100Vac de-rate power by 1% / Vac
Operating Humidity5 to 95% RH (Non-Condensing)
Overvoltage< 36 V, SELV Output Latch Mode
Overload / Overcurrent101 - 150% of rated load current, Auto-recovery Continuous current limit Mode (Vo > 80%)
Over TemperatureLatch Mode
Degree of ProtectionIP20
Protection Against ShockClass II (No Primary Earth connection is required)
Internal FuseT3.15 A / 250 V
MTBFTelcordia SR-332: > 700,000 hrs I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25 DegreeC
Expected Cap Life Time10 years (115 Vac & 230 Vac, 50% load @ 40 DegreeC)
Electrical SafetyCB scheme: IEC 62368-1, IEC/EN/BS EN 61010-1/-2-201, IEC 60335-1, IEC/EN/BS EN 61558-1/-2-16 TUV Bau
Galvanic IsolationInput to Output 4.0 kVac
UKCAIn conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility
EmissionCISPR 32, EN/BS 55032, AS/NZS CISPR32, EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN/BS 61000

Minimum order quantity: 1 Piece

Analog Corporation Offer The Chrome II Series is Delta’s latest DIN rail power supply. It features 15 W / 30 W / 60 W / 100 W models with up to 92.16 W maximum output. It has 12 V, 24 V, and 48 V nominal voltage outputs and accepts 85-264 Vac universal voltage input. It boasts a compact design to be aligned with DIN 43880, a standard that defines dimensions for distribution boards of building control and home automation systems. The Series is also certified to IEC/EN 60335-1, IEC 61558-1, and IEC 61558-2-16 to ensure electrical safety for distribution boards. All the above features make the Series suitable for building automation and household appliances. The double-isolated input eliminates the need of an earth connection for a low leakage current. It complies to DOE VI energy efficiency standard with its lower no-load power consumption. 

Highlights & Features
  • Class II, Double Isolation (No Earth connection is required)
  • Mechanical dimensions are designed to meet DIN 43880 for building automation
  • Low no load power consumption and compliance with DOE VI efficiency standard
  • NEC Class 2 / Limited Power Source (LPS) certified
  • Over Voltage Category III